Low Smoke Zero Halogen Photovoltaic Cable Material - China Suppliers and Factory Offering High-Quality Insulation Solutions
| No. | Inspection item | Unit | Requirements | ||
|---|---|---|---|---|---|
| WDZ-Y-J70 | WDZ-Y-H70 | WDZ-Y-H90 | |||
| 1 | Tensile strength | MPa | ≥10.0 | ≥10.0 | ≥10.0 |
| 2 | Elongation at break | % | ≥160 | ≥160 | ≥160 |
| 3 | Air aging chamber | ||||
| Aging temperature | ℃ | 100±2 | 100±2 | 110±2 | |
| Aging time | h | 168 | 168 | 240 | |
| Maximum rate of change of tensile strength | % | ±25 | ±25 | ±25 | |
| Maximum rate of change of elongation at break | % | ±25 | ±25 | ±25 | |
| 4 | Thermal deformation | ||||
| Test temperature | ℃ | 90±2 | 90±2 | 90±2 | |
| Experimental result | % | ≤50 | ≤50 | ≤50 | |
| 5 | 20℃ volume resistivity | Ω·m | ≥1.0×1012 | ≥1.0×1010 | ≥1.0×1010 |
| 6 | Volume resistivity at operating temperature | ||||
| Test temperature | ℃ | 70±1 | — | — | |
| Volume resistivity | Ω·m | ≥2.0×108 | — | — | |
| 7 | Dielectric strength | MV/m | ≥20 | ≥18 | ≥18 |
| 8 | Heat shock test | ||||
| Test temperature | ℃ | 130±3 | 130±3 | 130±3 | |
| Test time | h | 1 | 1 | 1 | |
| Experimental result | — | No cracking | No cracking | No cracking | |
| 9 | Impact embrittlement temperature | ||||
| Test temperature | ℃ | -25 | -25 | -25 | |
| Experimental result | Number | ≤15/30 | ≤15/30 | ≤15/30 | |
| 10 | Ozone resistance test | ||||
| Test temperature | ℃ | — | 25±2 | 25±2 | |
| Experiment time | h | — | 24 | 24 | |
| Ozone concentration | ppm | — | 250~300 | 250~300 | |
| Experimental result | — | — | No cracking | No cracking | |
| 11 | Hot water immersion test | ||||
| Test temperature | ℃ | — | 70±2 | 70±2 | |
| Experiment time | h | — | 168 | 168 | |
| Maximum rate of change of tensile strength | % | — | ±30 | ±30 | |
| Maximum rate of change of elongation at break | % | — | ±35 | ±35 | |
| 12 | Oxygen index | % | ≥28 | ≥30 | ≥30 |
| 13 | Smoke density | ||||
| flameless | — | ≤350 | ≤350 | ≤350 | |
| flaming | — | ≤100 | ≤100 | ≤100 | |
| 14 | Combustion releases gas acidity | ||||
| HCI and HBr content | % | ≤0.5 | ≤0.5 | ≤0.5 | |
| HF content | % | ≤0.1 | ≤0.1 | ≤0.1 | |
| pH value | — | ≥4.3 | ≥4.3 | ≥4.3 | |
| Electric conductivity | μS/mm | ≤10 | ≤10 | ≤10 | |
| 15 | Material smoke toxicity hazards | According to the application requirements of the product, negotiated by the supply and demand parties. | |||
It can withstand outdoor, ultraviolet, temperature changes, and adverse weather conditions to ensure reliability in various climatic conditions.
Yes, it uses low smoke zero halogen materials that have high fire resistance, protecting the internal insulation and preventing the spread of fire.
In the event of a fire, the low smoke zero halogen material produces less smoke and lower toxic gas, improving personnel evacuation safety and reducing toxicity risks.
Yes, it has good electrical insulation to ensure safe power transmission under high voltage, reducing the risk of electric shock and fire.
The primary scope of use for this product is as a photovoltaic cable.
According to the test standards, the oxygen index requirement is ≥28% for WDZ-Y-J70, and ≥30% for WDZ-Y-H70 and WDZ-Y-H90 models.