Leave Your Message
Low Smoke Zero Halogen Coaxial Cable Material - China Suppliers and Factory for Superior Performance and Safety

Low Smoke Zero Halogen Coaxial Cable Material - China Suppliers and Factory for Superior Performance and Safety

Our premium cable materials feature remarkable characteristics such as low smoke emission, high flame retardancy, low toxicity, excellent temperature resistance, weatherproof capabilities, superior dielectric properties, and effective anti-ultraviolet attenuation. As a leading factory in China, we collaborate with top experts and professors from renowned chemical colleges to ensure our products meet the highest industry standards. Our dedicated project experimental group focuses on delivering tailored solutions for our clients, solidifying our position as a competitive supplier in the market. Choose us for innovative and reliable cable materials that stand out in the industry.

    Product Features

    Low smoke combustion This cable material produces less smoke in the event of a fire, which helps to improve the safety of personnel evacuation.
    High Flame retardant With good flame retardant performance, can slow the spread of fire, reduce fire losses.
    Low toxicity There are fewer harmful substances in the smoke produced, which is less harmful to human health.
    High temperature resistance Can maintain stable performance in high temperature environment, suitable for various industrial applications.
    Weather resistance It has the ability to resist ultraviolet light and climate change, which extends the service life of the cable.
    High dielectric property It has good electrical insulation performance, which can effectively prevent short circuit or fault of wire and cable.
    Environmental protection Does not contain harmful halogen compounds, helping to reduce the negative impact on the environment.
    Anti-ultraviolet attenuation It has anti-ultraviolet attenuation characteristics to extend the service life of the cable.

    Scope of Use

    Cable and optical cable, coaxial cable, network cable, elevator cable, etc. The special materials used in other industries need to be communicated by telephone, such as power cord materials, electronic wire materials, injection molding products, automotive wire materials, casing materials, water pipes, audio wire materials, injection plastics, transparent materials, etc.
    drg (1)qiv
    drg (1)cwj
    drg (2)9ko
    drg (3)b9s

    Test Items and Standards

    Properties of halogen-free low smoke flame retardant thermoplastic polyolefin insulating materials and sheathing materials.

    No. Inspection Item Unit WDZ-Y-J70 WDZ-Y-H70 WDZ-Y-H90
    1 Tensile strength MPa ≥10.0 ≥10.0 ≥10.0
    2 Elongation at break % ≥160 ≥160 ≥160
    3 Air aging chamber
    — Aging temperature 100±2 100±2 110±2
    — Aging time h 168 168 240
    — Max rate of change of tensile strength / elongation % ±25 ±25 ±25
    4 Thermal deformation
    — Test temperature / Result ℃ / % 90±2 / ≤50 90±2 / ≤50 90±2 / ≤50
    5 20℃ volume resistivity Ω·m ≥1.0×10¹² ≥1.0×10¹⁰ ≥1.0×10¹⁰
    6 Volume resistivity at operating temperature
    — Test temperature / Resistivity ℃ / Ω·m 70±1 / ≥2.0×10⁸
    7 Dielectric strength MV/m ≥20 ≥18 ≥18
    8 Heat shock test
    — Test temperature 130±3 130±3 130±3
    — Test time / Result h / — 1 / No cracking 1 / No cracking 1 / No cracking
    9 Impact embrittlement temperature
    — Test temp / Result ℃ / Number -25 / ≤15/30 -25 / ≤15/30 -25 / ≤15/30
    10 Ozone resistance test
    — Test temperature 25±2 25±2
    — Experiment time h 24 24
    — Ozone concentration / Result ppm / — 250~300 / No cracking 250~300 / No cracking
    11 Hot water immersion test
    — Test temperature 70±2 70±2
    — Experiment time h 168 168
    — Max rate of change (tensile / elongation) % ±30 / ±35 ±30 / ±35
    12 Oxygen index % ≥28 ≥30 ≥30
    13 Smoke density
    — Flameless / Flaming ≤350 / ≤100 ≤350 / ≤100 ≤350 / ≤100
    14 Combustion releases gas acidity
    — HCI and HBr content % ≤0.5 ≤0.5 ≤0.5
    — HF content % ≤0.1 ≤0.1 ≤0.1
    — pH value / Electric conductivity — / μS/mm ≥4.3 / ≤10 ≥4.3 / ≤10 ≥4.3 / ≤10
    15 Material smoke toxicity hazards According to the application requirements of the product, negotiated by the supply and demand parties.

    Certifications

    Certification 1
    Certification 2
    Certification 3
    Certification 4

    Frequently Asked Questions

    What are the primary features of this halogen-free low smoke cable material?

    The material features low smoke combustion, high flame retardancy, low toxicity, high temperature resistance, weather resistance, high dielectric properties, environmental protection, and anti-ultraviolet attenuation.

    Where can these special materials be used?

    They are widely used for cables and optical cables, coaxial cables, network cables, and elevator cables. Other applications like automotive wire materials, water pipes, or injection molding products require specific communication.

    Is the material safe for the environment and human health?

    Yes, it produces less smoke and lower toxicity in the event of a fire. Furthermore, it does not contain harmful halogen compounds, significantly reducing the negative impact on the environment.

    What is the typical tensile strength requirement for WDZ-Y-J70?

    According to the technical standards, the tensile strength requirement for WDZ-Y-J70 is ≥10.0 MPa, with an elongation at break of ≥160%.

    Does the material withstand high temperatures effectively?

    Yes, the material can maintain stable performance in high-temperature environments. For instance, it successfully undergoes air aging chamber tests at temperatures up to 110±2 ℃ for 240 hours without severe degradation.